Tag: US Cabling Pros

In these modern times, every business onsite IT support needs a reliable cabling system to handle their voice and data needs, and if you do not want any untoward delay in your operations due to a massive system failure then you should only get the services of reliable structured data cabling services. As the years pass, more and more technological innovations seem to pop out of the woodwork, and this is all the more reason why you should get a cabling system that can manage all of these new devices and infrastructures so your business can reap all of their benefits.

Why choose structured cabling?

As the name suggests, structured data cabling provides you with an organized system that you can connect all of your important office devices with each other. If you opt for a cheap cabling installation, then there is a huge chance that most, if not the entire system may not be able to function at its fullest; and if you are not making full use of your data network, then you can akin it to throwing money in the toilet.

A good structured cabling system will enable all of your data and voice equipment to interact with each other the way that they are meant to. You can also expect a good cabling system to be able to function properly for many years to come, it should also be able to provide you with provisions for expansion should you need it.

How should the cabling get installed?

Different companies have different needs, and this is also the same with structured cabling systems. So during your consultation with your chosen low-voltage data cabling services, you need to ascertain that they know your company’s particular needs and expectations; and they should also be aware of the local ordinances regarding the kind of project they will be undertaking.

How to find the right structured cabling services?

To make sure that you are dealing with reputable structured and low voltage data cabling services you need to look for a couple of important details; like finding out if they are using modern and high quality materials, and if they in partnership with reputable leaders in the cabling industry. You can also check out the companies’ references for past clients so you can get a bit of feedback about them; if you hear mostly good things, then you have a keeper in your hands.

Tags: , , , , , , , , , , , , , , , , , , , , ,

Plenum-rated data cable is derived from an old HVAC term referring to “plenum spaces”.  A plenum space is the division of a building that facilitates air circulation by providing pathways for heated/air-conditioned and return air-flows at a higher pressure than typical.

Simply put, plenum rated low voltage data cabling has an extra fire retard applied to the shielding portion of the cable making it more resistant to heat and less likely to cause fires vs. non-plenum cable which does not have this extra layer of fire protection.

Plenum Cat5 Data Cable

Plenum Cat5 Data Cable for Low Voltage Data Cabling

The choices Onsite IT Computer Services available for different cable products these days are very abundant. Everyday new options are being introduced into the electrical market. Whether it be from the parameters changing to the different variations, the choices are becoming more and more plentiful as time goes on. One option; however, which is usually the first thing a person takes into consideration when purchasing cable remains pretty constant. This is whether or not the cable to be used will need to be plenum rated or Non-Plenum rated.

There are two basic types of building construction as it regards the movement of heating, air conditioning and ventilation through office buildings. In these modern times, every business needs a reliable cabling system to handle their voice and data needs, and if you do not want any untoward delay in your operations due to a massive system failure then you should only get the services of reliable IT data cabling services. As the years pass, more and more technological innovations seem to pop out of the woodwork, and this is all the more reason why you should get a cabling system that can manage all of these new devices and infrastructures so your business can reap all of their benefits.

In newer construction and in most high-rise construction the architects save space and the cost of expensive sheet metal return air ducts by simply drawing the air back to the heating/air condition unit through the open spaces above the ceiling and between the walls.

Tags: , , , , , , , , , , , , , ,

Commercial Onsite IT Network Services spaces (e.g. data closets, server rooms) typically use a elevated flooring system for the server racks. This enables intensive cooling to be expelled through the space under the floor to cool the servers, switches, routers, etc. Cabling between the many devices and to the users runs through this open floor layout. This by definition is a Plenum Air space and requires Plenum Rated Cable. Onsite IT Support.

If there is no wall or ceiling return air grate; look closely at your fluorescent lighting fixtures to see if there is a gap around the edge of the fixtures and put your hand over the gap and you can feel air movement. Obviously your air conditioner should be running at the time! The lack of wall or ceiling return air grates is usually a sure sign that you require Plenum Rated Cable. If you have a large wall or ceiling return air grate; remove and see if there the air is channeled through sheet metal ducting. If there is no sheet metal duct; just the open ceiling or wall space, then you are required by law to use Plenum Rated cable.

How should the data cabling get installed?

Different companies have different needs, and this is also the same with structured cabling systems. So during your consultation with your chosen onsite data cabling services, you need to ascertain that they know your company’s particular needs and expectations; and they should also be aware of the local ordinances regarding the kind of project they will be undertaking.

This is an important issue related to the chemical composition of the cable and your building‘s construction, especially when it comes to your small business phone system and low voltage data/audio cabling.

Since both you and the Fire Department don‘t want you to die from breathing in toxic fumes from your cabling, code requires Plenum Rated cable installed through any plenum air return space. Our Installation Team is required run Plenum Rated cable if they determine the air space in not ducted.